Quick Search: Hit CONTROL-F to search THIS page with your browser! |
![]() | Hard to find Tektronix CRTs (Cathode Ray Tubes), Shields and LCDs | ![]() |
Welcome To Sphere Research's Canadian Test Equipment & Parts Site! | ||||
![]() Click REFRESH on your browser if pages seem unchanged ![]() Everything from Quotes and SciFi to Ethics & Business. ![]() ![]() ![]() | ![]() Please Note: All Prices are in US$ |
Sphere Research Corporation 3394 Sunnyside Rd. West Kelowna, BC, Canada V1Z 2V4 Phone: +1 (250) 769-1834 A great source for test equipment, repairs, calibrations, useful metrology information, and of course, SLIDE RULES! Just ![]() |
![]() ![]() Parts by the Foot! |
Now OPEN, our ![]() Literally millions of parts available at great prices! |
![]() |
![]() ![]() |
I'm in a HURRY! Show me all the: | ![]() |
![]() |
![]() |
![]() |
![]() ![]() ![]() ![]() Tektronix CRTs, LCDs & Magnetic Shields ![]() ![]() Tektronix / Tek Cathode Ray Tubes (CRTs) ![]() ![]() ![]() ![]() You can order anything here just by picking up the phone, and calling (250) 769-1834 during normal office hours, 8:30AM to 4:30PM PST, OR, Email your order to Susan ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]()
|
E-mail us | Want something? Click here to e-mail us! We accept Visa / MC for fast order processing. |
Tube Number
154-0699-00
154-0732-00
154-0917-00
85ACB31
315, 360154-0366-00
154-0519-00, -01
154-0667-00, -01
154-0667-02, -03
154-0726-05
154-0466-00
154-0666-10
154-0492-04
154-0630-10
154-0630-00
154-0505-00
154-0619-00
-07/-12 P2, -08/13 P7, -09/14 P11154-0731-00
154-0676-15
154-0731-00154-0731-00
154-0777-00
154-0677-10
154-0652-00/05
154-0502-00/05
154-0809-00
154-0699-00
154-0730-00/05/08
154-0246-00
154-0248-00154-0812-00
154-0730-05
154-0859-00
Standard/P31, orange graticule154-0825-00
154-0525-10
154-0514-10
154-0089-00
154-0409-00
154-0758-00
154-0478-00, 154-0568-00
154-0449-00
567
568154-0613-00
154-0531-00
154-0410-00
154-0565-00
154-0343-00
154-0562-00
604A154-0633-05, 10
154-1271-00
154-0656-00
154-0885-00/01
154-0667-02
154-0929-00
154-0838-00
154-0838-00
154-0969-00
154-0861-00
2236154-0861-00
154-0905-00
2336
2337154-0832-00
154-0850-01
154-0850-00/01
154-0850-00/01
154-0850-00/01
154-0633-10
154-0572-10
154-0635-00
154-0701-00, 05
-05 subs.
-08/P7, -09/P11. 154-0684-00 opt. 2 only.154-0783-00
154-0682-02/10
154-0640-00, 05
154-0622-00
154-0640-00
154-0822-00154-0672-00/05
154-0673-00
154-0670-00, 10
154-0723-00
154-0721-00
154-0609-00
154-0644-05
154-0713-00
154-0644-05
154-0893-05
Possibly 154-0644-05
YOURS HERE?Try this great Tek Reference Site for more help
All kinds of useful Tek info!
More cross reference data and service / troubleshooting info located at the bottom of this page! |
E-mail us | Want something? Click here to e-mail us! We accept Visa / MC for fast order processing. |
MANUFACTURER/ NOTES | |||
![]() ![]() LCD Color Shutter (for CRT Displays) Tek p/n- CS-0010 |
![]() ![]() ![]() ![]() New, factory bagged LCD color shutters that can translate a monochrome CRT display to typically red, green and yellow by operating the nominally transparent LCD shutter to form different transmissive colors. This shutter is for the obscure Tektronix TFP2A, an Optical Time Domain Reflectometer, but may be useful for experiments or elsewhere. Shutter active area approx. 5 1/2 inches by 4 1/4 inches. Interconnect is via a 4 wire ribbon cable with 4 pin/0.1 inch pitch connector. |
![]() ![]() NIB $39 ea. |
|
Tek p/n- 154-0366-00 |
![]() Miniature Round, 3 Inch Flat Face Electrostatic CRT, for Tektronix early 3 inch portables, filament tested good, P31. Very hard tube to find. |
![]() $25 |
|
![]() ![]() ![]() 323, 324 CRT Tek p/n- 154-0519-00 |
![]() ![]() Miniature Rectangular Electrostatic CRT, for Tektronix 323/324 portables, new stock, but unboxed, filament tested good. Very hard tube to find. |
![]() $95 |
E-mail us | Want something? Click here to e-mail us! We accept Visa / MC for fast order processing. |
MANUFACTURER/ NOTES | |||
![]() ![]() 7704A / 7903/ 7904 CRT Tek p/n- 154-0644-00
|
![]() ![]() Rectangular Electrostatic CRT, for Tektronix 7704A, 7903 or 7904 scope. FULLY TESTED, in 7904, and checked for brightness and focus, PRIME TUBE, LOOKS GOOD. |
![]() $80 Shield, $10 |
|
![]() ![]() 7704A / 7903/ 7904 CRT Tek p/n- 154-0644-05 |
![]() Rectangular Electrostatic CRT, for Tektronix 7704A, 7903 or 7904 scope. FULLY TESTED, in 7704A, and checked for brightness and focus, PRIME TUBES, LOOK GOOD. |
![]() $80 Shield, $10 |
|
![]() ![]() ![]() 1502/1503/305/326 CRT Tek p/n- 154-0667-02 |
![]() Miniature rectangular Electrostatic CRT, with special graticule for 1502 TDR. Made by SONY, also marked 3E070, which is probably a date code. New tube, bulk packed. Filament tested good, LOOKS GOOD. |
![]() ![]() $80 |
|
Tek p/n- 154-0676-10 |
![]() Rectangular Electrostatic high speed CRT for 100Mhz 465/465B scopes, P31. Fully tested, excellent brightness and focus, very good cosmetic condition. Tough tube to find in good condition! |
![]() $80 |
|
Tek p/n- 154-0677-10 |
![]() Rectangular Electrostatic high speed CRT for 200Mhz 475/475A scopes, P31. Good physical condition, tested, very hard to find. |
![]() $95 |
|
Tek p/n- 154-0730-05 |
![]() Miniature Rectangular Electrostatic CRT for SC502/4 scope module, very hard to find. |
![]() $95 |
|
![]() ![]() TLD75, 455, 465, 465B 468 CRT Tek p/n- 154-0731-00 |
465/465B CRTs...Fix your favorite scope!![]() Rectangular Electrostatic CRT, for Tektronix 465B/468 and related portable scopes, P31 standard phoisphor. Filament tested good, removed from functional unit, LOOK VERY GOOD, minimal use, late date codes. See also -0777 CRT as a possible sub. |
![]() |
![]() $85 |
![]() ![]() TLD75, 455, 465, 465B 468 CRT Tek p/n- 154-0731-04 |
465/465B CRTs...Fix your favorite scope!![]() Rectangular Electrostatic CRT, for Tektronix 465B/468 and related portable scopes, but has P11 bright blue phoisphor! Filament tested good, removed from functional unit, LOOK VERY GOOD, minimal use, late date codes. See also -0777 CRT as a possible sub. |
![]() |
![]() $80 |
![]() ![]() 465M CRT Tek p/n- 154-0777-00 |
![]() Rectangular Electrostatic CRT, for Tektronix 465M, but can also work in related portable scopes. Filament tested good, removed from functional units, LOOKS VERY GOOD, minimal use. |
![]() $65 |
|
Tek p/n- 154-0798-00 |
![]() Rectangular Electrostatic low speed CRT for 620 series display, P31, NO GRATICULE. Good physical condition, tested, very hard to find. |
![]() $65 |
|
Tek p/n- 154-0822-00 |
![]() Large Rectangular Electrostatic high speed CRT for 7603 scopes, P31. Good physical condition, tested, very hard to find. |
![]() $75 |
|
![]() ![]() 2335, 2336, 2337 Tek p/n- 154-0832-00 |
![]() ![]() Rectangular Electrostatic CRT, for Tektronix 2335, 2336, and 2337 scopes, with integral rotation coils. Filaments tested good, very low use (units had approx. 3500 hrs on internal clock), looks like new, VERY HARD TO FIND! Also have SHIELD assy. available for this tube, $10, excellent condition. |
![]() $80 |
|
Tek p/n- 154-0838-00 |
![]() Rectangular Electrostatic meduium speed CRT for 22xx series scopes, P31. Good physical condition, tested, very hard to find. |
![]() $65 |
|
![]() ![]() 2430/40/45/55 and 2465/A/B Tek p/n- 154-0850-01 + wiring |
![]() ![]() Rectangular Electrostatic CRT, for Tektronix 2430/2445/2455/2465A/B and related high speed scopes, with integral rotation coils. The tubes left are all with the added ribbon cable wiring for digital models 2430/A and 2440, please note this, as all have the same part number! This wiring can be easily removed for use in other models like the 2465 etc.. |
![]() $80 |
|
![]() ![]() ![]() Late SC504 CRT Tek p/n- 154-0859-00 |
![]() Miniature Rectangular Electrostatic CRT, for Tektronix SC504 80Mhz TM500 series scope. Filament and function tested good, low use, looks great, VERY HARD TO FIND! Tube is not the exact one pictured, but same type. CLICK HERE for SCREEN Close-Up. This is the hardest Tek tube for us to source, and availability is very poor, we have to break up a scope to get one. |
![]() $95 |
|
Tek p/n- 154-0861-00 |
![]() Rectangular Electrostatic high speed CRT for 22xx series scopes, P31. Good physical condition, tested, very hard to find. |
![]() $85 |
|
![]() 2246/A Tek p/n- 154-0905-00 |
![]() Rectangular Electrostatic CRT, for Tektronix 2246/A and proably others in that series. Filament tested good, very good condition, removed from working units. |
![]() $70 |
|
![]() ![]() 2216 CRT Tek p/n- 154-0969-00 |
![]() ![]() Rectangular Electrostatic CRT for compact late production scopes such as 2216, with integral rotation coil assy., HV lead and shield (removable). Brand new tube removed from incomplete factory Tek assembly. Shield included. |
![]() |
Odd waveform distortion (humps, curves, sudden angles) that is in the same physical place on the CRT (regardless of control settings) especially of very unusual shape, is generally caused by:
1. Magnetic interference: this can be accidentally magnetized parts within the CRT, adjacent hardware or an external source. move the scope, if the interference is unchanged, degauss the tube and chassis with a standard TV degaussing coil (or any home made one excited by AC). If this improves matters, keep looking for the exact offending part, and degauss again, or remove the hardware that is magnetized. You can usually cure this problem, but it is time consuming. Severe magnetic distortion can be caused by a single magnetized screw in the wrong place. Don't sit a scope on top of a speaker cabinet or by speakers,, or near anything with a magnetron in it, the results can be serious.
2. Mechanical distortion within the tube: if the above technique doesn't work, the tube or scope has probably been dropped, and the shock has broken or bent an internal electrode or support. If the tube exhibits the identical distortion outside the chassis, with the shield removed, it is damaged, and has to be replaced.
Other CRT issues:
3. If the display is crooked relative to the gracticule lines (goes at an angle), this is almost always the trace rotation adjustment, which may not be easy to find or readily accessible in some models. Generally, it is DC bias applied to a coil around the CRT neck, you may be able to find the control by following the coil wires back to the PC board. It is VERY common for this to be out of adjustment after shipping. calibration is not affected.
4. If the display is turned up or down at the corners, or has an angled appearance, it is probably the geometry adjustment, and this can be complex to set, you must use the manual and follow the CRT alignment carefully. Calibration is affected. Some scopes have supplemental X or Y axis alignment as well, generally via coils.
5. If strange trace effects occur at the face of the tube when touched, it probably indicates high static build up on the display filter, or tube face. Clean the parts, then wipe everything down with a standard anti-static wipe, the effect will disappear. Plastic can be very highly charged when rubbed with a synthetic cloth for cleaning. Use a damp cotton cloth or anti-static wipe to avoid this effect
.Tek number cross reference for older CRT's courtesy of:
Craig Sawyers email- c.sawyers@tech-enterprise.com -
5ABP1 - 154-0068-00 5ABP7 - 154-0069-00 5ABP11 - 154-0070-00 5BGP1/T51P1A - 154-0080-00 5BGP2/T51P2A - 154-0081-00 5BGP7/T51P7A - 154-0082-00 5BGP11/T51P11A - 154-0083-00 5BGP16/T51P16A - 154-0092-00 5BGP24/T51P24A - 154-0124-00 5BHP1/T54P1 - 154-0106-00 5BHP2/T54P2 - 154-0098-00 5BHP7/T54P7 - 154-0104-00 5CAP1/T52P1 - 154-0093-00 5CAP2/T52P2 - 154-0097-00 5CAP7/T52P7 - 154-0102-00 5CAP11/T52P11 - 154-0103-00 5CAP16/T52P16 - 154-0162-00 5CBP1/T55P1 - 154-0125-00 5CBP2/T55P2 - 154-0120-00 5CBP7/T55P7 - 154-0126-00 5CBP11/T55P11 - 154-0127-00 5CBP16/T55P16 - 154-0161-00 5CBP24/T55P24 - 154-0177-00 T502P1/T60P1 - 154-0172-00 T502P2/T60P2 - 154-0144-00 T502P7/T60P7 - 154-0170-00 T502P11/T60P11 - 154-0173-00 T517P1H/T54P1H - 154-0107-00 T517P2H/T54P2H - 154-0109-00 T517P7H/T54P7H - 154-0108-00 T517P11H/T54P11H - 154-0105-00 T517P16H/T54P16H - 154-0128-00 T536P1/T56P1 - 154-0140-00 T536P2/T56P2 - 154-0133-00 T536P7/T56P7 - 154-0135-00 T536P11/T56P11 - 154-0136-00 T536P16/T56P16 - 154-0169-00 T551P1/T57P1 - 154-0186-00 T551P2/T57P2 - 154-0160-00 T551P7/T57P7 - 154-0189-00 T551P11/T57P11 - 154-0143-00 515A and RM15 ============= 5CBP1/T55P1 - 154-0125-00 5CBP2/T55P2 - 154-0120-00 5CBP7/T55P7 - 154-0126-00 5CBP11/T55P11 - 154-0127-00 5CBP16/T55P16 - 154-0161-00 5CBP24/T55P24 - 154-0177-00 536 === T536P1/T56P1 - 154-0140-00 T536P2/T56P2 - 154-0133-00 T536P7/T56P7 - 154-0135-00 T536P11/T56P11 - 154-0136-00 T536P16/T56P16 - 154-0169-00 551 === T551P1/T57P1 - 154-0186-00 T551P2/T57P2 - 154-0160-00 T551P7/T57P7 - 154-0189-00 T551P11/T57P11 - 154-0143-00 502 === T502P1/T60P1 - 154-0172-00 T502P2/T60P2 - 154-0144-00 T502P7/T60P7 - 154-0170-00 T502P11/T60P11 - 154-0173-00 524AD 5ABP1 - 154-0068-00 5ABP7 - 154-0069-00 5ABP11 - 154-0070-00 531, 535, RM31, RM35 ==================== 5BGP1/T51P1A - 154-0080-00 5BGP2/T51P2A - 154-0081-00 5BGP7/T51P7A - 154-0082-00 5BGP11/T51P11A - 154-0083-00 5BGP16/T51P16A - 154-0092-00 5BGP24/T51P24A - 154-0124-00 525, 532, RM32, 570, 575 ======================== 5CAP1/T52P1 - 154-0093-00 5CAP2/T52P2 - 154-0097-00 5CAP7/T52P7 - 154-0102-00 5CAP11/T52P11 - 154-0103-00 5CAP16/T52P16 - 154-0162-00 517A ==== T517P1H/T54P1H - 154-0107-00 T517P2H/T54P2H - 154-0109-00 T517P7H/T54P7H - 154-0108-00 T517P11H/T54P11H - 154-0105-00 T517P16H/T54P16H - 154-0128-00 541, 545, RM41, RM45 ==================== 5BHP1/T54P1 - 154-0106-00 5BHP2/T54P2 - 154-0098-00 5BHP7/T54P7 - 154-0104-00 5BHP11/T54P11 - 154-0099-00 5BHP16/T54P16 - 154-0118-00 5BHP24/T54P24 - 154-0152-00 And here's some more, where x denotes the phosphor. The scope type can then be used to get the 154 number from Stan's site. 316, RM16, RS16 =============== T316Px/T32Px 503, 504 ======== T503Px 526 === T526Px 531A, RM31A, 533, RM33, 535A, RM35A =================================== T533Px/T64Px 541A, RM41A, 543, RM43, 545A, RM45A =================================== T543Px/T65Px 555 === T551Px/T59Px 581, 585 ======= T581Px 507 === T507Px/T53Px 519 ==== T519A - P11 phosphor only 551 listed above was later replaced by T5511Px 502 listed above was later replaced by T5021Px
Want to join a Tek Scope eGroup mail list for information about these great instruments? Just Click on the link to the right to subscribe or view the information on line. | ![]() CLICK to visit the Tek Scopes eGroup |
IMPORTANT ! Graphical logos and trademarks are the property of their respective owners, including Tektronix, Fluke, RCA, TI, GE, General Radio and Hewlett Packard, and are used here merely to unambiguously identify the products. Sphere Research IS NOT a factory authorized distributor for any of the product lines indicated. | ![]()
| ||
![]() | You are visitor number
![]() ![]() Site Design & contents copyright 1997, 1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2014, 2020 by Walter Shawlee 2 & the ad hoc Godzilla Graphics Group. All rights reserved.
|